Add to Cart
650ml 1:1 Two Components Chemcial Anchor Adhesive For Structural Strengthening
Chemical anchor adhesive, epoxy injection mortar, Chemical fixing glue,
Chemical anchoring system used for anchoring and rebar connections in concrete.
Item #: FixingChor142
Capacity: 420ml
Materials: Epoxy
Mixing Ratio: 2:1
ATTENTION
-Do not install anchors when substrate temperature is less than 0°C.
-Do not install anchors when the temperature is less than 10°C.
-At temperatures below 10°C should be warmed or stored in temperatures
of 10-30°C for 24hours prior to use to improve product flow and cure.
-If the gelling time expires, please use a new static mixer.
-Do not cut or shorten nozzles.
-If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.
-It can be used again in the future by replacing the static mixer.
-Please ensure hole is properly cleaned. Hole may be damp but must be free from water.
-Do not dilute mortar with any solvents and/or other chemicals.
-Not suitable for use in diamond cored holes without roughening.
-Please ensure spiral mixer in nozzles.
-Do not install into uncured concrete.
-Please use Xinchor nozzles, other nozzles may cause ineffective mixing
and reduce the properties of the mortar.
Ultimate-performance injectable hybrid mortar with approvals for rebar connections and heavy-duty anchoring
Base materials: Concrete (cracked), Concrete (uncracked), Masonry (grout-filled CMU)
Base material condition: Dry, Wet
Features
No hole cleaning required with metal anchor rod
Automatic hole cleaning with drill bits in combination with Hilti vacuum cleaners
Fulfills the requirements of the most demanding ICC-ES and ETA C2 approvals for seismic applications
Working time optimized for anchor applications
Suitable for use in cracked and uncracked concrete with all anchor rods and rebar
Testing project | Condition | Index | ||
Gel Performance (According to China National Standard GB50728-2011) | ||||
Splitting Tensile Strength (MPa) | Under (23±2)℃,(50±5)%RH, tested by loading speed of 2mm/min | ≥8.5 | ||
Flexural Strength (MPa) | ≥50 (no fragment damage) | |||
Compressive Strength (MPa) | ≥60 | |||
Bonding Capacity (According to China National Standard GB50728-2011) | ||||
Steel-Steel Tensile Shear Strength (MPa) | (23±2)℃,(50±5)%RH | ≥10 | ||
Bonding strength of Ribbed steel bar (or screw) with concrete under constrain drawing condition | (23±2)℃ (50±5)%RH | C30,Ф25,L=150mm | ≥11 | |
C60,Ф25,L=150mm | ≥17 | |||
Steel-Steel T-peeling strength (mm) | (23±2)℃,(50±5)%RH | ≤25 | ||
Non-volatile content | (105±2)℃,(180±5)min | ≥99% | ||
Ageing resistance to heat and humidity 90d | ||||
Reduction rate of tensile strength | Under normal room temperature | ≤12% | ||
(According to China National Standard JGJ145-2013) | ||||
Tensile Strength (after high temperature welding) | Dia12 Grade II steel, C30 concrete Hole dia.16mm, Depth: 150mm | 55.1N, 57.0N, 54.8N |
Approved for anchorings in
Railway or express way modification works
Structure reinforcement
Curtain wall installing
Concrete, cracked and non-cracked Applications
Rebar planting in concrete structures.
Bridge modification works
Keel fixing in out wall
ATTENTION
- Do not install anchors when the temperature is less than 10°C.
- If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.
- At temperatures below 10°C should be warmed or stored in temperatures
of 10-30°C for 24hours prior to use to improve product flow and cure.
- If the gelling time expires, please use a new static mixer.
- Do not cut or shorten nozzles.
- It can be used again in the future by replacing the static mixer.
- Please ensure hole is properly cleaned. Hole may be damp but must be free from water.
- Do not install anchors when substrate temperature is less than 0°C.