Add to Cart
1000ml 1:1 Cartrige Epoxy Chemcial Anchor Adhesive For Structural Strengthening
Chemical anchor adhesive, epoxy injection mortar, Chemical fixing glue,
Chemical anchoring system used for anchoring and rebar connections in concrete.
Item #: FixingChor110
Capacity: 1000ml
Materials: Epoxy
Mixing Ratio: 3:1
Application Range
For structural work:
Rebar / steel reinforcement anchoring in new and refurbishment works.
Threaded rods
Bolts and special fastening systems
Mechanical and electrical services installation
Anchoring of supports for ducting and equipment.
Metal Work, carpentry
Fixing of handrails, balustrades and supports
Fixing of railings
Fixing of window and door frames
Fixing of the following substrates:
Concrete
Hard natural and reconstituted stone
Solid rock and masonry
Steel
Wood
Suitable for
Non-cracked concrete
Reinforcement bars
For fixing of:
Steel constructions
Testing Items | Condition | Index | ||
Adhesive Performance (According to China National Standard GB50728-2011) | ||||
Splitting Tensile Strength (MPa) | Under (23±2)℃,(50±5)%RH, tested by loading speed of 2mm/min | ≥8.5 | ||
Flexural Strength (MPa) | ≥50 (no fragment damage) | |||
Compressive Strength (MPa) | ≥60 | |||
Bonding Capacity (According to China National Standard GB50728-2011) | ||||
Steel-Steel Tensile Shear Strength (MPa) | (23±2)℃,(50±5)%RH | ≥10 | ||
Bonding strength of Ribbed steel bar (or screw) with concrete under constrain drawing condition | (23±2)℃ (50±5)%RH | C30,Ф25,L=150mm | ≥11 | |
C60,Ф25,L=150mm | ≥17 | |||
Steel-Steel T-peeling strength (mm) | (23±2)℃,(50±5)%RH | ≤25 | ||
Non-volatile content | (105±2)℃,(180±5)min | ≥99% | ||
Ageing resistance to heat and humidity 90d | ||||
Reduction rate of tensile strength | Under normal room temperature | ≤12% | ||
(According to China National Standard JGJ145-2013) | ||||
Tensile Strength (after high temperature welding) | Dia12 Grade II steel, C30 concrete Hole dia.16mm, Depth: 150mm | 55.1N, 57.0N, 54.8N |
Approved for anchorings in
Railway or express way modification works
Structure reinforcement
Curtain wall installing
Concrete, cracked and non-cracked Applications
Rebar planting in concrete structures.
Bridge modification works
Keel fixing in out wall
ATTENTION
- Do not install anchors when the temperature is less than 10°C.
- If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.
- At temperatures below 10°C should be warmed or stored in temperatures
of 10-30°C for 24hours prior to use to improve product flow and cure.
- If the gelling time expires, please use a new static mixer.
- Do not cut or shorten nozzles.
- It can be used again in the future by replacing the static mixer.
- Please ensure hole is properly cleaned. Hole may be damp but must be free from water.
- Do not install anchors when substrate temperature is less than 0°C.